When Panic Station can't be searched in SADP, can't ping IP successfully or the is crashed. In this situation, control panel need to be upgraded by RS232 cable.
Important Note: Computer must close the firewall.

1. laptop USB port with Panic Station by RS232 cable.

2. Check the COM port in computer's device .

3. Open SecureCRT and below parameters.

4. Hold down the Enter key when the Panic Alarm station power on.

5. Enter b.

6. Then enter pri , check device start IP environment.

7. Change device IP environment during time.(address set depend on your network environment)
setenv serverip 10.9.98.35;
setenv ipaddr 10.9.98.20;
setenv gatewayip 10.9.98.254
— serverip :PC
— ipaddr :Device
— gatewayip :Gateway address

8. Enter pri again, check these IP address have been changed.

9. Enter ping 10.9.98.35 , check device and PC is connected.
Host 10.9.98.35 is alive means connection is ok.

10. Copy to the tftp catalog, then open tftp.

11. Enter .

12. successful.